Volume 19, Number 1 (4-2015)                   hmj 2015, 19(1): 59-65 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Dehghani M, Sheibani Seresht S, Taghizadeh M M. Optimization of organic compounds removal from Wastewater by Electrocoagulation. hmj. 2015; 19 (1) :59-65
URL: http://hmj.hums.ac.ir/article-1-1453-en.html

Department of Environmental Engineering
Abstract:   (1266 Views)

Introduction: As the most hazardous sewage, hospital wastewater contains various contaminants, and its uncontrolled discharge can seriously damage the environment. Bandar Abbas is located in an arid and semi-arid region therefore, hospital wastewater should be treated through an appropriate and economic method. This study aimed to determine the efficiency of electrocoagulation with aluminum and iron electrodes in removal of COD from wastewater of Shahid Mohammadi Hospital of Bandar Abbas. Methods: This analysis was performed in laboratory-scale through an incoherent method using a reactor which contained iron and aluminum binary and quaternary electrodes. A total of 55 samples of raw sewage of the hospital were examined and a total of 216 samples were analyzed to determine the parameters which were effective in the process. Samples (3 L) were immediately transferred to the laboratory after collection. COD removal was performed through electrocoagulation at pH 3, 7, and 11, voltages 10, 20, and 30, and reaction times of 30, 45, and 60 min. The results were analyzed using SPSS 16 through analysis of covariance. Results: The data showed better performance of electrodes at 2 cm apart rather than 3 cm. The COD removal efficiency was increased by 6.2% when pH was decreased from 11 to 3 at optimum voltage of 30 V and reaction time of 60 min. The results showed that by increasing the reaction time from 30 to 60 min at voltages 10, 20 and 30, the efficiency of COD removal increased from 32.3% to 87.1%. Therefore, the highest efficiency of COD removal (87.1%) was obtained at optimal pH of 3, voltage of 30 V, and reaction time of 60 min with iron quaternary electrode. Conclusion: Given the high efficiency of electrocoagulation as well as its simplicity and relatively low cost, it can be used for removal of COD from hospital wastewater.

Keywords: Hospital - Wastewater – Electrocoagulation
Citation: Dehghani M, Sheibani Seresht S, Taghoizadeh MM. Optimization of organic compounds removal from Wastewater by Electrocoagulation. Hormozgan Medical Journal 2015;19(1):59-65.
Full-Text [PDF 281 kb]   (593 Downloads)    
Type of Study: Research | Subject: General
Received: 2015/07/1 | Accepted: 2015/07/1 | Published: 2015/07/1

Add your comments about this article : Your username or email:
Write the security code in the box

Send email to the article author


© 2015 All Rights Reserved | Bimonthly Journal of Hormozgan University of Medical Sciences

Designed & Developed by : Yektaweb
Creative Commons License