Volume 18, Number 1 (4-2014)                   hmj 2014, 18(1): 67-74 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mahvi A, Alipour V, Rezaei L, Nohegar A, Hosainzadeh M. Qualitative and quantitative study of water obtained from condensate atmosphere humidity in Bandar Abbas air conditioners. hmj. 2014; 18 (1) :67-74
URL: http://hmj.hums.ac.ir/article-1-1178-en.html

Department of Environmental Health
Abstract:   (2650 Views)

Introduction: Earth's atmosphere contains billion cubic meters of fresh water, which is considerable as a reliable water resource, especially insultry areas. What is important in this context, how to extract the water, in an economic manner. In order to extract water from air conditioner, no need to spend any cost, because water produced as a by-product and trouble production. The aim of study was to evaluate the quantity and chemical quality of water obtained from Bandar Abbas air conditioners.

Methods: This cross - sectional study was conducted during March to December of 2010. Sixty six samples were taken in cluster random plan. Bandar Abbas divided into four clusters; based on distance to shore and population density. Chemical tests which included: turbidity, alkalinity, total hardness, dissolved solids (TDS) and electrical conductivity (EC) and quantity measurement were performed on them. T-test and ANOVA were used for statistical analysis.

Results: Obtained water had slightly acidic pH, near to neutral range. Total dissolved solids, electrical conductivity, total hardness and alkalinity of extracted water were in low rate. Each air conditioner produced 36 liter per day averagely. Split types obtained more water to window air conditioners.

Conclusion: With regard to some assumptions, approximately 4680 to 9360 cubic meter per day water is obtainable which is suitable for many municipal and industrial water applications.

Keywords: Atmospheric Moisture - Water Extraction – Condensation - Bandar Abbas
Citation: Mahvi A.H, Alipour V, Rezaei L, Nohegar A, Hosainzadeh M.M. Qualitative and quantitative study of water obtained from condensate atmosphere humidity in Bandar Abbas air conditioners. Hormozgan Medical Journal 2014;18(1):67-74.
Full-Text [PDF 472 kb]   (3097 Downloads)    
Type of Study: Research | Subject: General
Received: 2014/03/8 | Accepted: 2014/03/8 | Published: 2014/03/8

Add your comments about this article : Your username or email:
Write the security code in the box

Send email to the article author


© 2015 All Rights Reserved | Bimonthly Journal of Hormozgan University of Medical Sciences

Designed & Developed by : Yektaweb
Creative Commons License